# Leak Detection > Leak Detection: Tube and tube-joint vacuum testing Our field teams test tubes and tube-to-tubesheet joints with vacuum leak detectors. One operator seals the… - Source: Hefei Lanbo Electric Machines and Tools Technology Co., Ltd. (Lanbo) - URL: https://hflanbo.com.cn/en/service/rejiaohuanqijianloufuwu.html - Last updated: 2026-10-17 - Phone: +86-551-6288 4258 / +86-551-6287 6222 / +86-551-6288 4054 / +86-136 3706 6767; Email: Lanbo@hflanbo.com.cn; Address: 159 Tiandu Road, Hefei Economic and Technological Development Zone, Hefei, Anhui 230601, China ## Details Tube and tube-joint vacuum testing Our field teams test tubes and tube-to-tubesheet joints with vacuum leak detectors. One operator seals the far end of the tube with a plug, presses the nozzle into the near end and pulls the trigger: compressed air through a venturi pulls a vacuum in the tube. A steady gauge reading means a tight tube; a falling reading means a leak. With clean, dry air at 90 psi a standard tube (25.4 mm OD × 0.9 mm) is tested in seconds. Locating micro-leaks When condenser tubes or tube joints show small leaks, including in nuclear plants, our engineers locate the leaking tubes and joints and carry out the repair or plugging. ## FAQ ### How do I enquire about Leak Detection? Call +86-551-6288 4258 / +86-551-6287 6222 / +86-551-6288 4054 / +86-136 3706 6767 or email Lanbo@hflanbo.com.cn with your equipment type, tube material and schedule, and we will connect you with a technician.